Callout |
Component Name |
---|---|
Preliminary Procedure
|
|
1 |
Air Conditioning Compressor Bolt (Qty :3) Caution: Refer to Fastener Caution.
22 Y (16 lb ft) |
2 |
Air Conditioning Compressor Assembly Procedure
When replacing the air conditioning compressor, balance the compressor oil. Refer to Air Conditioning Compressor Oil Balancing. |
Hood Rear Weatherstrip Replacement
in
Hood Rear Weatherstrip Replacement
Callout
Component Name
1
Hood Rear Weatherstrip
Procedure
The hood rear weatherstrip is held in place with 10?€‰plastic retainers
that are part of the air inlet grille. ...
Heating and Air Conditioning System Description and Operation
Engine Coolant
Engine coolant is the key element of the heating system. The engine thermostat
controls the normal engine operating coolant temperature. Coolant pumped out
of the engine enters the heater core through the inlet heater hose. The air
flowing through the HVAC module abs ...
Torque Converter Installation
Torque Converter Installation
Callout
Component Name
1
Torque Converter Assembly
Note: Failure to lower the torque converter straight down
could damage the torque converter clutch lip seal inside the torque ...