OnStar Additional Information
AccessoriesRemote Keyless Entry (RKE) System Operation
The RKE transmitter may work up to 60?€‰m (195?€‰ft) away from the vehicle.
Other conditions can affect the performance of the transmitter. See Remote Keyless
Entry (RKE) System.
RKE without Remote Start Shown
The following buttons are on the transmitter:
Q ...
Windshield Wiper System Module Replacement
Windshield Wiper System Module Replacement
Callout
Component Name
Preliminary Procedures
Open and support the hood assembly.
Remove the air inlet grille panel. Refer to Air Inlet Grille Panel
Replacement.
...
Crankshaft Position System Variation Learn
Note: The crankshaft position sensor system variation learn procedure
is required when the following service procedures have been performed, regardless
of whether DTC P0315 is set:
Engine replacement
Engine control module (ECM) replacement
Crankshaft damper replacement
...