The Secondary Air Injection System aids in the reduction of hydrocarbon exhaust emissions during a cold start. This occurs when the start-up engine coolant temperature (ECT) is between −10 to +56°C (14?E33°F), the intake air temperature (IAT) is greater than −10°C (14°F) and it has been more than 60 minutes since the last engine start. The secondary air injection pump operates 5?E0 s after start-up.

The engine control module (ECM) activates the secondary air injection system by simultaneously completing the ground paths for the secondary air injection pump relay and the secondary air injection solenoid (shutoff and check) valve relay. This action closes the relays' internal contacts. The pump and valve are in turn energized. The pump turns ON and the valve opens.

The secondary air injection pump sends pressurized filtered fresh air into the pipe/hose, through the open valve and into the exhaust manifold. The extra air accelerates the catalyst operation, helping it to reach operating temperature faster. The secondary air injection pump remains ON for a short period of time after the valve is commanded OFF. When the pump is commanded OFF it will not run or be activated until the next vehicle cold start. When the secondary air injection system is inactive, the valve is closed to prevent air/exhaust flow in either direction.

The ECM monitors the secondary air injection system pressure by tracking voltage signal from the pressure sensor, which is integral to the solenoid (shutoff and check) valve assembly.

The ECM utilizes a 3 phase diagnostic routine to test the secondary air injection system:

During phase 1, DTCs P0411 and P2430 run and both the secondary air injection pump and the solenoid (shutoff and check) valve are activated. Normal secondary air function occurs. Expected system pressure is 5?E3 kPa (0.7?E.9 psi) above BARO.

During phase 2, DTCs P2430 and P2440 run and only the secondary air injection pump is activated. The valve is closed. Pressure sensor performance and valve deactivation are tested. Expected system pressure is 14?E5 kPa (2.0?E.6 psi) above BARO.

During phase 3, DTC P2444 runs and neither the secondary air injection pump nor the valve are activated. Secondary air injection pump deactivation is tested. Expected system pressure equals BARO.

The secondary air injection system includes the following components:

System Fault Detection

The ECM monitors the secondary air injection system for faults during cold start operation. When the system's pressure or relay circuits operations vary too far from the expected values, a DTC will set. Diagnostics detect the following conditions:

  • A partially or fully blocked or leaking secondary air injection system
  • A malfunctioning secondary air injection pump
  • A malfunctioning secondary air injection solenoid (shutoff and check) valve assembly
  • A malfunctioning secondary air injection pressure sensor
  • A restricted exhaust system
  • A malfunctioning secondary air injection pump and secondary air injection valve relay

The following DTCs set when a secondary air injection system fault is detected:

  • DTC P0411 ?EA secondary air injection system insufficient airflow fault condition has been detected.
  • DTC P0412 ?EA secondary air injection valve relay coil circuit fault condition has been detected.
  • DTC P0418 ?EA secondary air injection pump relay coil circuit fault condition has been detected.
  • DTC P2430 ?EA secondary air injection pressure sensor signal stuck in range fault condition has been detected.
  • DTC P2431 ?EA skewed air injection pressure sensor signal has been detected.
  • DTC P2432 ?EA secondary air injection pressure sensor signal voltage below the minimum range of the sensor fault condition has been detected.
  • DTC P2433 ?EA secondary air injection pressure sensor signal voltage is above the maximum range of the sensor fault condition has been detected.
  • DTC P2440 ?EThe solenoid (shutoff and check) valve is stuck open or a system leak between the pump and the valve has been detected.
  • DTC P2444 ?EA secondary air injection pump stuck ON fault condition has been detected.
Secondary Air Injection Pump Replacement
Secondary Air Injection Pump Replacement Callout Component Name 1 Secondary Air Injection Pump Inlet Pipe Note: ...

Catalytic Converter
...

Other materials:

Remote Control Door Lock Receiver Replacement
Remote Control Door Lock Receiver Replacement Callout Component Name Preliminary Procedure Remove the windshield outside moisture sensor cover. Refer to Windshield Outside Moisture Sensor Cover Replacement. ...

Turn Signal Multifunction Switch Replacement
.. Turn Signal Multifunction Switch Replacement Callout Component Name Preliminary Procedure Remove the upper trim cover and the lower trim cover from the steering column. Refer to Steering Column Lower Trim Cover Replacemen ...

Cylinder Head Installation
Special Tools EN-45059 Torque Angle Sensor Kit For equivalent regional tools, refer to Special Tools. Clean the sealing surfaces. Inspect for plane surface. Cylinder block, cylinder head Straight-edge, feeler gauge Install the cylinder head gasket. Install the cylinder head. ...

© 2014-2024 Copyright www.csmans.com
 
0.0066