Chevrolet Sonic manuals

Chevrolet Sonic Repair Manual: Torque Converter Housing with Fluid Pump Assembly Installation (6T30)

Chevrolet Sonic Repair Manual / Powertrain / Transmission/Transaxle / Transmission Oil Cooler / Torque Converter / Torque Converter Housing with Fluid Pump Assembly Installation (6T30)



Torque Converter Housing with Fluid Pump Assembly Installation

Callout

Component Name

1

Fluid Pump Seal Assembly

2

Torque Converter Housing Gasket

3

Torque Converter (w/Fluid Pump) Housing Assembly

Note:

Rotate the differential slightly in each direction using DT-48277 rotating tool to align the Differential Pinion Gears with the Differential Ring Gear in the Torque Converter Housing.

Special Tool

DT-48277 Differential Rotating Tool

For equivalent regional tools, refer to Special Tools.

4

Torque Converter and Differential Housing Bolts M8 x 30 (Qty: 14)

Caution:

Refer to Fastener Caution.

Procedure

Tighten the bolts in sequence shown.

Tighten


10 Y (89 lb in) then rotate the bolt an additional 50 degrees

Special Tool

EN-45059 Angle Meter or equivalent

For equivalent regional tools, refer to Special Tools.

Torque Converter Housing Cleaning and Inspection
Torque Converter Housing Cleaning and Inspection Callout Component Name Caution: After cleaning the transmission components, a ...

Torque Converter Housing with Fluid Pump Assembly Installation (6T40/45/50 Non Hybrid)
Torque Converter Housing with Fluid Pump Assembly Installation Callout Component Name 1 Fluid Pump Seal Assembly ...

Other materials:

Tire-to-Wheel Match-Mounting (Vectoring)
Note: After remounting a tire to a wheel or after replacing a tire and/or a wheel, remeasure the tire and wheel assembly runout in order to verify that the amount of runout has been reduced and brought to within tolerances. Ensure that the tire and wheel assembly is properly balanced ...

Park - Engine Running (Gen 1)
When the gear selector lever is in the Park (P) position, fluid is drawn into the pump through the transmission fluid filter assembly. Line pressure is then directed to the following valves: Fluid Pressure Directed in Preparation for a Shift Manual Valve Mechanically controlled ...

Shift Fork Cleaning and Inspection (Gen 2)
Warning: Wear safety glasses to avoid injury when using compressed air or any cleaning solvent. Bodily injury may occur if fumes are inhaled or if skin is exposed to chemicals. Clean the following components with a suitable solvent. Air dry all the parts. 3rd and ...