Callout |
Component Name |
|---|---|
|
1 |
Fluid Pump Seal Assembly |
|
2 |
Torque Converter Housing Gasket |
|
3 |
Torque Converter (w/Fluid Pump) Housing Assembly Note: Rotate the differential slightly in each direction using DT-48277 rotating tool to align the Differential Pinion Gears with the Differential Ring Gear in the Torque Converter Housing. Special Tool
DT-48277 Differential Rotating Tool For equivalent regional tools, refer to Special Tools. |
|
4 |
Torque Converter and Differential Housing Bolts M8 x 30 (Qty: 14) Caution: Refer to Fastener Caution. Procedure
Tighten the bolts in sequence shown. Tighten
10 Y (89 lb in) then rotate the bolt an additional 50 degrees Special Tool
EN-45059 Angle Meter or equivalent For equivalent regional tools, refer to Special Tools. |
Torque Converter Housing Cleaning and Inspection
Torque Converter Housing with Fluid Pump Assembly Installation (6T40/45/50 Non
Hybrid)Tire-to-Wheel Match-Mounting (Vectoring)
Note: After remounting a tire to a wheel or after replacing a tire
and/or a wheel, remeasure the tire and wheel assembly runout in order to verify
that the amount of runout has been reduced and brought to within tolerances.
Ensure that the tire and wheel assembly is properly balanced ...
Park - Engine Running (Gen 1)
When the gear selector lever is in the Park (P) position, fluid is drawn into
the pump through the transmission fluid filter assembly. Line pressure is then directed
to the following valves:
Fluid Pressure Directed in Preparation
for a Shift
Manual Valve
Mechanically controlled ...
Shift Fork Cleaning and Inspection (Gen 2)
Warning: Wear safety glasses to avoid injury when using compressed
air or any cleaning solvent. Bodily injury may occur if fumes are inhaled
or if skin is exposed to chemicals.
Clean the following components with a suitable solvent.
Air dry all the parts.
3rd and ...