Callout |
Component Name |
---|---|
1 |
Fluid Pump Seal Assembly |
2 |
Torque Converter Housing Gasket |
3 |
Torque Converter (w/Fluid Pump) Housing Assembly Note: Rotate the differential slightly in each direction using DT-48277 rotating tool to align the Differential Pinion Gears with the Differential Ring Gear in the Torque Converter Housing. Special Tool
DT-48277 Differential Rotating Tool For equivalent regional tools, refer to Special Tools. |
4 |
Torque Converter and Differential Housing Bolts M8 x 30 (Qty: 14) Caution: Refer to Fastener Caution. Procedure
Tighten the bolts in sequence shown. Tighten
10 Y (89 lb in) then rotate the bolt an additional 50 degrees Special Tool
EN-45059 Angle Meter or equivalent For equivalent regional tools, refer to Special Tools. |
Disarming the System
To disarm the system, either unlock the doors using the RKE transmitter, or start
the vehicle with a recognized transmitter in the vehicle.
To avoid setting off the alarm by accident:
Press on the RKE transmitter.
Start the vehicle.
To avoid setting off the alarm by accident:
Lock t ...
Brake Rotor Surface and Wear Inspection
Warning: Refer to Brake Dust Warning.
If the inboard friction surface of the brake rotor is not accessible, reposition
and support the caliper with the brake pads. Refer to Front Disc Brake Pads
Replacement.
Clean the friction surfaces of the brake rotor with denatured alcohol, or ...
Water Outlet Replacement (LUV)
Removal Procedure
Drain the engine coolant system. Refer to Cooling System Draining and
Filling.
Remove the following:
Engine coolant air bleed hose (1)
Engine coolant temperature sensor (2) and connector clip (3)
Heated oxygen senso ...