Callout |
Component Name |
---|---|
1 |
Fluid Pump Seal Assembly |
2 |
Torque Converter Housing Gasket |
3 |
Torque Converter (w/Fluid Pump) Housing Assembly Note: Rotate the differential slightly in each direction using DT-48277 rotating tool to align the Differential Pinion Gears with the Differential Ring Gear in the Torque Converter Housing. Special Tool
DT-48277 Differential Rotating Tool For equivalent regional tools, refer to Special Tools. |
4 |
Torque Converter and Differential Housing Bolts M8 x 30 (Qty: 14) Caution: Refer to Fastener Caution. Procedure
Tighten the bolts in sequence shown. Tighten
10 Y (89 lb in) then rotate the bolt an additional 50 degrees Special Tool
EN-45059 Angle Meter or equivalent For equivalent regional tools, refer to Special Tools. |