Callout |
Component Name |
---|---|
1 |
Fluid Pump Seal Assembly |
2 |
Torque Converter Housing Gasket |
3 |
Torque Converter (w/Fluid Pump) Housing Assembly Note: Rotate the differential slightly in each direction using the rotating tool to align the Differential Pinion Gears with the Differential Ring Gear in the Torque Converter Housing.
For equivalent regional tools, refer to Special Tools. |
4 |
Torque Converter and Differential Housing Bolts M8 x 30 (Qty: 15) Caution: Refer to Fastener Caution. Procedure
Tighten the bolts in sequence shown. Tighten
10 Y (89 lb in) then rotate the bolt an additional 50 degrees Special Tool
EN-45059 Angle Meter or equivalent For equivalent regional tools, refer to Special Tools. |
HVAC System Control Module Programming and Setup
Note:
DO NOT program a control module unless directed to by a service procedure
or a service bulletin. If the control module is not properly configured
with the correct calibration software, the control module will not control
all of the vehicle features properly.
Ensure th ...
Drive and Driven Sprocket, Drive Link, and Park Pawl Installation (6T40/45/50)
Drive and Driven Sprocket, Drive Link, and Park Pawl Installation
Callout
Component Name
1
Front Differential Carrier Baffle
2
Front Differential Carrier Baffle Bolt M6 x 16& ...
Transmission Rear Mount Bracket Replacement
Removal Procedure
Raise and support the vehicle. Refer to
Lifting and Jacking the Vehicle.
Remove the front suspension skid plate, if equipped.
Refer to Drivetrain and Front Suspension Frame Skid
Plate Replacement.
Using a suitable jack stand, support the rear of the ...