Note:
Do not apply the brake pedal during the brake pedal position sensor calibration procedure. Any movement of the brake pedal during this procedure will cause the calibration procedure to fail. If this occurs, the brake pedal position sensor calibration must be repeated.
Brake pedal position sensor calibration must be performed after the brake pedal position sensor, body control module?€‰(BCM), or engine control module (ECM) have been serviced. The calibration procedure will set the brake pedal position sensor home value. This value is used by the BCM and ECM to determine the action of the driver applying the brake system and to provide this information to the vehicle subsystems via serial data.
Overview (AM-FM Radio)
1. FAV (Favorites)
Radio: Opens the favorites list.
2. /VOL (Power/Volume)
Turns the system on or off and adjusts the volume.
3. Buttons 1−6
Radio: Saves and selects favorite stations.
4. SEEK
Radio: Seeks the next station.
CD: Selects the next track or fast forw ...
What to Use
Warning
Adding only plain water or some other liquid to the cooling system can be
dangerous. Plain water and other liquids, can boil before the proper coolant mixture
will. The coolant warning system is set for the proper coolant mixture. With plain
water or the wrong mixture, the engine coul ...
Ambient Air Temperature Sensor Replacement
\/\\//\\\\(in
Ambient Air Temperature Sensor Replacement
Callout
Component Name
Preliminary Procedures
Raise and support the vehicle. Refer to Lifting and Jacking the
Vehicle.
Remove the front bumper fascia opening lower c ...