Warning:
Refer to Gasoline/Gasoline Vapors Warning.
Note:
The fuel tank must be drained with a suitable, commercially-available fuel removal unit and suction hose - follow safety regulations and national legislation. The fuel tank is fitted with a refill limit float valve. This is located on the filler neck in the fuel tank. To prevent damaging the refill limit float valve, a suitable suction hose must be used. In the presence of fuel vapors or escaping fuel - observe safety regulations and national legislation. Store drained fuel in a suitable, sealable container.
Fuel Injection Fuel Rail Assembly Replacement
Fuel Tank Filler Door Latch Housing ReplacementGeneral Plastic Repair
Warning: In order to reduce the risk of personal injury when exposed
to toxic fumes while grinding, cutting, or applying repair material on any type
of sheet molded compound or RIM rigid plastic, observe the following guidelines:
Work in a properly ventilated area
Apply protecti ...
Instrument Panel Center Molding Replacement (With U58)
Instrument Panel Center Molding Replacement
Callout
Component Name
1
Instrument Panel Center Molding Assembly
Procedure
Use a flat bladed plastic trim tool in the shown locations, then
rotate the trim tool 90 ...
Hydraulic Brake System Bleeding (Pressure)
Special Tools
CH-29532 Diaphragm Type Brake Pressure Bleeder
CH-35589-A Brake Pressure Bleeder Adapter
Warning: Refer to Brake Fluid Irritant Warning.
Caution: Refer to Brake Fluid Effects on Paint and Electrical Components
Caution.
Place a clean shop cloth beneath the b ...