Callout |
Component Name |
---|---|
1 |
Torque Converter and Differential Housing Bolts M8 x 30 (Qty: 15) |
2 |
Torque Converter with Fluid Pump Housing Assembly |
3 |
Torque Converter Housing Gasket Note: Discard the seal. It is not reusable. |
4 |
Fluid Pump Seal Assembly Note: Discard the seal. It is not reusable. |
Indicator/Warning Message Description and Operation
Indicator LIGHT ON
Refer to the owner's manual for the descriptions and explanations of all
indicator lights.
For diagnosis and repair information related to an indicator light, refer
to the System Diagnosis and the Description of Operation that the message relates
to.
...
Fuel Tank Filler Door Replacement
Fuel Tank Filler Door Replacement
Callout
Component Name
1
Fuel Tank Filler Door
Procedure
Position the fuel tank filler door to the full open position. Using light
outward sliding pressure on the filler door, ...
Oil Pump Replacement
Removal Procedure
Remove the engine front cover. Refer to Engine Front Cover with Oil
Pump Replacement.
Remove the 8 oil pump cover bolts (1).
Remove the oil pump cover (2).
Warning: Before removing the spring, cover the spring with ...