Crankcase Ventilation System Inspection/Diagnosis
Results of Incorrect Operation
A plugged positive crankcase ventilation (PCV) orifice or hose may cause
the following conditions:
Rough idle
Stalling or slow idle speed
Oil leaks
Oil in the throttle body
Sludge in the engine
Functional Check
With thes ...
Exhaust Manifold Installation
Clean the exhaust manifold sealing surface.
Install a NEW exhaust manifold gasket (1) to the cylinder head.
Caution: Refer to Fastener Caution.
Caution: Refer to Torque-to-Yield Fastener Caution.
Install the exhaust manifold (3) and tighten the NEW nu ...
Neutral - Engine Running (Gen 1)
When the gear selector is moved to the Neutral (N) position, the hydraulic and
electrical system operation is identical to Park (P) range. However, if Neutral
is selected after the vehicle was operating in Reverse (R), the normally-high 35R
pressure control solenoid 2 is commanded OFF and the ...